KM-55
Shielding Gas: CO2
KM-55 is suitable for welding 490, 520 and 540N/mm2 grade steel at high current and interpass temperature.
Ideal for welding pillars and beams at high current
Shielding Gas: CO2
KM-55 is suitable for welding 490, 520 and 540N/mm2 grade steel at high current and interpass temperature.
Ideal for welding pillars and beams at high current
| AWS A5.18 | ER80S-G |
| JIS Z3312 | YGW18 |
| EN 14341-A | G50 0 C1 Z |
| GB T8110 | ER50-G |
Please refer to Appendix B.
Ideal for welding pillars and beams at high current
| C | Si | Mn | P | S |
| 0.100 | 0.48 | 1.07 | 0.019 | 0.009 |
| Tensile Strength N/mm2 | Yield Strength N/mm2 | Elongation % | Charpy V-Notch ℃ | Charpy V-Notch J |
| 579 | 500 | 28 | 0 -20 | 137 |
| Diameter (mm) | 1.2 | 1.4 | 1.6 |
| F/H-fillet | 200~350 | 250~450 | 300~550 |
| H | 200~320 | 250-400 | 300-450 |